Enterprise-Grade
Infrastructure & Hosting

Equinix co-location, active-active multi-site failover, and sub-millisecond cross-connects — the backbone behind institutional execution quality that never sleeps.

3Global Equinix Sites
99.98%Uptime SLA
<0.2msCross-connect RTT
Active-ActiveFailover Mode

Three Primary Equinix Locations

Production infrastructure deployed at the three most critical financial Equinix hubs — direct cross-connects to matching engines, prime brokers, and Tier-1 LP venues.

Equinix LD4 — London

Primary production site. Slough, UK. Direct cross-connects to LME, ICE Europe, and all major European LP bank matching engines. Lowest latency for EMEA sessions.

PrimaryEMEA session

Equinix NY4 — New York

Secaucus, NJ. Cross-connected to CME, NYSE, and major North American LP venues. Active production node for US and Latin American session flow.

PrimaryUS/LATAM session

Equinix TY3 — Tokyo

Osaka 2 campus. Asia-Pacific execution node. Cross-connects to JPX, TSE, and key APAC LP venues. Optimised for JPY, AUD, NZD, and SGD flow.

PrimaryAPAC session

Active-Active Multi-Site Architecture

WINPROPRIME does not operate active-passive. All three Equinix sites handle live production traffic simultaneously, with automatic rerouting in the event of a site or network failure.

Active-ActiveAll Sites Live
<100msAutomatic Failover
99.98%Production Uptime SLA
Zero RPORecovery Point Objective
01

Multi-Site Active Serving

All production FIX sessions, pricing engine components, and risk management services run simultaneously across at least two data centres. No cold standby.

02

Automatic Failover

Network health monitoring at <10ms intervals. On site or path failure, new connections route to the next-nearest Equinix site with sub-100ms switchover.

03

Synchronised State

Order state, position state, and session sequence numbers replicated synchronously across sites. No position gaps or sequence resets on failover.

04

Independent Power & Network Paths

Each Equinix site fed by multiple power sources and network carriers. No single-vendor dependency for network transit or power delivery.

Network Connectivity Options

Multiple paths to WINPROPRIME infrastructure, from standard internet to dedicated physical cross-connect inside Equinix.

Equinix Cross-Connect

Physical cross-connect cable between your cage and WINPROPRIME within the same Equinix facility. Minimum RTT, maximum determinism.

<0.2msPhysical layer

VPN Tunnel (IPSec)

Dedicated IPSec VPN tunnel for clients not co-located at an Equinix facility. Deterministic, private, with full encryption. Available LD4, NY4, TY3.

IPSec3 locations

Internet (TLS 1.3)

Standard internet FIX sessions with TLS 1.3. IP whitelist enforced. Suitable for UAT, lower-volume clients, or geographic regions outside Equinix.

TLS 1.3IP whitelist

Infrastructure Security Framework

Every layer of the infrastructure stack is hardened, monitored, and auditable — designed to meet institutional counterparty security requirements.

Network Perimeter Security

Dedicated firewall appliances at each Equinix site. All inbound and outbound traffic statefully inspected. BGP route filtering and antispoofing enforced at edge.

Stateful inspectionBGP filtering

Encryption & Key Management

TLS 1.3 on all external sessions. Mutual certificate authentication for FIX clients. Encryption keys rotated on defined schedule. Session certificates pinned per-client.

TLS 1.3Mutual auth

Security Monitoring

24/5 security operations. IDS/IPS on all network perimeters. Log aggregation and SIEM with automated alerting. Out-of-band management network.

24/5 SOCIDS · IPS · SIEM

Backup & Restore

Full state backups at 4-hour intervals. Point-in-time restore of position state, order history, and FIX session journals. Recovery tested monthly.

4hr RPOMonthly DR test

Operational Support & SLAs

Infrastructure clients receive defined SLAs and 24/5 engineering coverage with named contacts and out-of-hours emergency escalation.

Production SLAs

Critical (full outage)15 min response · 1hr resolution
Major (degraded service)1hr response · 4hr resolution
Minor (non-critical)4hr response · next day

Monitoring & Alerting

Uptime monitoringEvery 30 seconds
Latency alertingP99 threshold breach
Capacity alertsCPU · memory · bandwidth

Change Management

Planned maintenance72hr notice minimum
Emergency changeImmediate notification
Post-incident reportWithin 24 hours

Discuss co-location requirements

Share your infrastructure requirements and we will design the connectivity and resilience setup for your operations.